@ARTICLE{Jermak_Czeslaw_Janusz_Comparison_2017, author={Jermak, Czeslaw Janusz and Piątkowski, Ryszard and Dereżyński, Janusz and Rucki, Miroslaw}, volume={vol. 64}, number={No 1}, pages={93-110}, journal={Archive of Mechanical Engineering}, howpublished={online}, year={2017}, publisher={Polish Academy of Sciences, Committee on Machine Building}, abstract={In the article, the authors analyze and discuss several models used to the calculation of air gauge characteristics. The model based on the actual mass flow (which is smaller than the theoretical one) was proposed, too. Calculations have been performed with a dedicated software with the second critical parameters included. The air gauge static characteristics calculated with 6 different models were compared with the experimental data. It appeared that the second critical parameters model (SCP) provided the characteristics close to the experimental ones, with an error of ca. 3% within the air gauge measuring range.}, type={Artykuły / Articles}, title={Comparison of the models of the air gauge static characteristics}, URL={http://www.journals.pan.pl/Content/104227/PDF/ame-2017-0006.pdf}, doi={10.1515/meceng-2017-0006}, keywords={air gauges, dynamic measurement, in-process control}, }