Search results

Filters

  • Journals
  • Date

Search results

Number of results: 1
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

This paper presents a study on the effect of cleaning factors on the energy consumption of the cleaning process in a CIP system, and the correlation between single components of electricity necessary to perform this process and the cleanliness degree obtained. Studies were carried out in a laboratory cleaning station, wherein a plate heat exchanger contaminated with hot milk was included. The research program was developed according to a 5-level statistical plan. Based on the results, obtained with Experiment Planner 1.0, a regression function of energy requirement considering variables such as: cleaning time, temperature and flow rate of the cleaning liquid via the cleaned exchanger has been developed. Describing this relationship, linear and quadratic functions with double interactions were used. Significance level for the analysis was established at α = 0.05. Correlation analysis between components of the electricity necessary to perform the cleaning process (pump drive and heating of the cleaning agent) and the resulting degree of cleaning of heat exchanger plates was performed.

Go to article

Authors and Affiliations

Joanna Piepiórka-Stepuk
Jarosław Diakun
Marek Jakubowski

This page uses 'cookies'. Learn more