Abstract

The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
Go to article

Bibliography

[1] Salij A., Stepien J.C.: Performance of Turbine Condensers in Power Units of Thermal Systems. Kaprint, Warsaw 2013 (in Polish).
[2] Rusowicz A.: Issues Concerning Mathematical Modelling of Power Condensers. Warsaw University of Technology, Warsaw 2013 (in Polish).
[3] Grzebielec A., Rusowicz A.: Thermal resistance of steam condensation in horizontal tube bundles. J. Power Technol. 91(2011), 1, 41–48.
[4] Laskowski R., Smyk A., Rusowicz A., Grzebielec A.: Selection of cooling water mass flow rate at variable load for 200 MW power unit. Rynek Energii (2020), 3,41– 46 (in Polish).
[5] Durmayaz A., Sogut O. S.: In?uence of cooling water temperature on the e?ciency of a pressurized-water reactor nuclear-power plant. Int. J. Energ. Res. 30(2006), 10, 799–810.
[6] Atria S.I.: The influence of condenser cooling water temperature on the thermal efficiency of a nuclear power plant. Ann. Nucl. Energy 80(2015), 371–378.
[7] Lakovic M.S., et.al. Stojiljkovic M.M. , Lakovic S.V., Stefanovic V.P., Mitrovic D.D.: Impact of the cold end operating conditions on energy efficiency of the steam power plants. Therm. Sci. 14(2010), Suppl., S53–S66.
[8] Laskowski R., Smyk A., Lewandowski J., Rusowicz A.: Cooperation of a steam condenser with a low-pressure part of a steam turbine in off-design conditions. Am. J. Energ. Res. 3(2015), 1, 13–18.
[9] Cengel Y.A.: Heat Transfer. McGraw-Hill, 1998.
[10] Holman J.P.: Heat Transfer. McGraw-Hill, New York 2002.
[11] Weber G.E., Worek W.M.: Development of a method to evaluate the design performance of a feedwater heater with a short drain cooler. J. Eng. Gas Turbines Power 116(1994), 2, 434–441.
[12] Weber G.E., Worek W.M.: The application of a method to evaluate the design performance of a feedwater heater with a short drain cooler. J. Eng. Gas Turbines Power 117(1995), 2, 384–387.
[13] Szkłowier G.G., Milman O.O.: Research and Calculations of Condensing Systems of Steam Turbines. Energoatomizdat, Moskwa 1985 (in Russian).
[14] Pattanayak L., Padhi B.N., Kodamasingh B.: Thermal performance assessment of steam surface condenser. Case Stud. Therm. Eng. 14(2019), 100484.
[15] Beckman G., Heil G.: Mathematische Modelle für die Beurteilung von Kraftwerksprozessen. EKM Mitteillungen (1965), 10.
[16] Laskowski R., Lewandowski J.: Simplified and approximated relations of heat transfer effectiveness for a steam condenser. J. Power Technol. 92(2012), 4, 258– 265.
[17] Laskowski R.M.: A mathematical model of the steam condenser in the changed conditions. J. Power Technol. 92(2012), 2, 101–108.
[18] Szapajko G., Rusinowski H.: Empirical modelling of heat exchangers in a CHP plant with bleed-condensing turbine. Arch. Thermodyn. 29(2008), 4, 177–184.
[19] Szapajko G., Rusinowski H.: Mathematical modelling of steam–water cycle with auxiliary empirical functions application. Arch. Thermodyn. 31(2010), 2, 165–183.
[20] Bahadori A.: Simple method for estimation of effectiveness in one tube pass and one shell pass counter-flow heat exchangers. Appl. Energ. 88(2011), 11, 4191–4196.
[21] Vera-García F., García-Cascales J.R., Gonzálvez-Maciá J., Cabello R., Llopis R., Sanchez D., Torrella E.: A simplified model for shell-and-tubes heat exchangers: practical application. Appl. Therm. Eng. 30(2010), 10, 1231–1241.
[22] Patrascioiu C., Radulescu S.: Modeling and simulation of the double tube heat exchanger. Case studies. Advances in Fluid Mechanics & Heat & Mass Transfer (P. Mastny, V. Perminov, Eds.). In: Proc. 10th WSEAS Int. Conf. on Heat Transfer, Thermal Engineering and Environment (HTE ’12) and Proc. 10th WSEAS Int. Conf. on Fluid Mechanics & Aerodynamics (FMA ’12), Istanbul, Aug. 21–23, 2012, WSEAS, 2012, 35–41.
[23] Patrascioiu C., Radulescu S.: Prediction of the outlet temperatures in triple concentric-tube heat exchangers in laminar flow regime: case study. Heat Mass Transfer 51(2015), 59–66.
[24] Laskowski R.: The black box model of a double-tube counter-flow heat exchanger. Heat Mass Transfer (2014), 10.1007/s00231-014-1482-2.
[25] Chmielniak T., Trela M., Eds.: Diagnostics of New-Generation Thermal Power Plants. Wyd. IMP PAN, Gdansk 2008.
[26] Butrymowicz D., Trela M.: Influence of fouling and inert gases on the performance of regenerative feedwater heaters. Arch. Thermodyn. 23(2002), 1-2, 127–140.
[27] Badur J., Kowalczyk T., Ziółkowski P., Tokarczyk P., Wozniak M.: Study of the effectiveness of the turbine condenser air extraction system using hydro ejectors. Trans. Inst. Fluid-Flow Mach. 131(2016), 41–53.
[28] Tokarczyk P.,Woznizk M., Badur J., Kowalczyk T., Ziółkowski P.: Issue of the temperature of water supplied to hydro ejector and its influence on performance of steam turbine condenser. Energetyka 70(2017), 10 (in Polish).
[29] HEI Standards for Steam Surface Condensers (11th Edn.). Heat Exchange Institute, Cleveland 2012.
[30] Prieto M.M., Suárez I.M., Montanés E.: Analysis of the thermal performance of a church window steam condenser for different operational conditions using three models. Appl. Therm. Eng. 23(2003), 2, 163–178.
[31] Wróblewski W., Dykas S., Rulik S.: Selection of the cooling system configuration for an ultra-critical coal-fired power plant. Energ. Convers. Manage. 76(2013), 554– 560.
[32] Jian-qun Xu, Tao Yang, You-yuan Sun, Ke-yi Zhou, Yong-feng Shi: Research on varying condition characteristic of feedwater heater considering liquid level. Appl. Therm. Eng., 67 (2014), 179–189.
[33] Laskowski R.: Relations for steam power plant condenser performance in off-design conditions in the function of inlet parameters and those relevant in reference conditions. Appl. Therm. Eng. 104(2016), 528–536.
[34] Laskowski R., Smyk A., Rusowicz A., Grzebielec A.: A useful formulas to describe the performance of a steam condenser in off-design conditions. Energy 204(2020) 117910.
[35] Wagner W., Kretzschmar H.J.: International Steam Tables – Properties of Water and Steam based on the Industrial Formulation IAPWS-IF97. Springer, 2008.
Go to article

Authors and Affiliations

Rafał Laskowski
1
Adam Smyk
1
Adam Ruciński
1
Jacek Szymczyk
1

  1. Institute of Heat Engineering, Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Nowowiejska 21/25, 00-665 Warsaw, Poland
Download PDF Download RIS Download Bibtex

Abstract

The paper presents an analysis of relations describing entropy generation in a condenser of a steam unit. Connections between entropy generation, condenser ratio, and heat exchanger effectiveness, as well as relations implied by them are shown. Theoretical considerations allowed to determine limits of individual parameters which describe the condenser operation. Various relations for average temperature of the cold fluid were compared. All the proposed relations were verified against data obtained using a simulator and actual measurement data from a 200 MW unit condenser. Based on data from a simulator it was examined how the sum of entropy rates, steam condenser effectiveness, terminal temperature difference and condenser ratio vary with the change in the inlet cooling water temperature, mass flow rate of steam and the cooling water mass flow rate.
Go to article

Authors and Affiliations

Rafał Laskowski
Maciej Jaworski
Adam Smyk
Download PDF Download RIS Download Bibtex

Abstract

In commercially available generation III and III+ PWR (pressurized water reactor) reactors, pressure of steam produced in steam generators varies in a relatively wide range from 5.7 to 7.8 MPa. Therefore, it is important to ask which value of steam pressure should be used for a specific unit, taking into account different location conditions, the size of the power system and conditions of operation with other sources of electricity generation.
The paper analyzes the effect of steam pressure at the outlet of a steam generator on the performance of a PWR nuclear power plant by presenting changes in gross and net power and efficiency of the unit for steam pressures in the range of 6.8 to 7.8 MPa. In order to determine losses in the thermal system of the PWR power plant, in particular those caused by flow resistance and live steam throttling between the steam generator and the turbine inlet, results concerning entropy generation in the thermal system of the power plant have been presented.
A model of a nuclear power plant was developed using the Ebsilon software and validated based on data concerning the Olkiluoto Unit 3 EPR (evolutionary power reactor) power plant. The calculations in the model were done for design conditions and for a constant thermal power of the steam generator. Under nominal conditions of the Olkiluoto Unit 3 EPR power unit, steam pressure is about 7.8 MPa and the steam dryness fraction is 0.997. The analysis indicates that in the assumed range of live steam pressure the gross power output and efficiency increase by 32 MW and 0.735 percentage point, respectively, and the net power output and efficiency increase by 27.8 MW and 0.638 percentage point, respectively.
In the case of all types of commercially available PWR reactors, water pressure in the primary circuit is in the range of 15.5−16.0 MPa. For such pressure, reducing the live steam pressure leads to a reduction in the efficiency of the unit. Although a higher steam pressure increases the efficiency of the system, it is necessary to take into account the limitations resulting from technical and economic criteria as well as operating conditions of the primary circuit, including the necessary DNBR (departure from nucleate boiling ratio) margin. For the above reasons, increasing the live steam pressure above 7.8 MPa (the value used in EPR units that have already been completed) is unjustified, as it is associated with higher costs of the steam generator and the high-pressure part of the turbine.
Go to article

Authors and Affiliations

Rafał Laskowski
1
Adam Smyk
1
Romuald Jurkowski
2
Julien Ancé
3
Marcin Wołowicz
1
Nikołaj Uzunow
1

  1. Warsaw University of Technology, Faculty of Power and Aeronautical Engineering, Institute of Heat Engineering, Nowowiejska 21/25, 00-665 Warszawa, Poland
  2. Framatome, 1 place Jean Millier, 92400, Courbevoie, Paris, France
  3. EDF, 19 rue Pierre Bourdeix, 69007, Lyon, France