Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 2
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a method of calculation of position deviations from a theoretical, nominally rectilinear trajectory for a SAR imaging system installed on board of UAV. The UAV on-board system consists of a radar sensor, an antenna system, a SAR processor and a navigation system. The main task of the navigation part is to determine the vector of differences between the theoretical and the measured trajectories of UAV center of gravity. The paper includes chosen results of experiments obtained during ground and flight tests.

Go to article

Authors and Affiliations

Michał Łabowski
Piotr Kaniewski
Stanisław Konatowski
Download PDF Download RIS Download Bibtex

Abstract

Background: The aim of the study was to answer two questions: 1 – Can data processing algorithms ensure sufficient accuracy for estimating human body pose via wearable systems? 2 – How to process the IMU sensor data to obtain the most accurate information on the human body pose? To answer these questions, the authors evaluated proposed algorithms in terms of accuracy and reliability. Methodology: data acquisition was performed with tested IMU sensors system mounted onto a Biodex System device. Research included pendulum movement with seven angular velocities (10-120°/s) in five angular movement ranges (30-120°). Algorithms used data from accelerometers and gyroscopes and considered complementary and/or Kalman filters with adjusted parameters. Moreover, angular velocity registration quality was also taken into consideration. Results: differences between means for angular velocity were 0.55÷1.05°/s and 1.76÷3.11%. In the case of angular position relative error of means was 4.77÷10.84%, relative error of extreme values was 2.15÷4.81% and Spearman’s correlation coefficient was 0.74÷0.89. Conclusions: Algorithm calculating angles based on acceleration-derived quaternions and with implementation of Kalman filter was the most accurate for data processing and can be adapted for future work with IMU sensors systems, especially in wearable devices that are designated to support human in daily activity.
Go to article

Authors and Affiliations

Aleksandra Szczerba
1
ORCID: ORCID
Piotr Prochor
1
ORCID: ORCID
Szczepan Piszczatowski
1
ORCID: ORCID

  1. Department of Biomaterials and Medical Devices Engineering, Institute of Biomedical Engineering, Faculty of Mechanical Engineering, BialystokUniversity of Technology, Wiejska 45C Street, 15-351 Bialystok, Poland

This page uses 'cookies'. Learn more