Treatment of leachate from an exploited since 2004 landfill by using two methods of advanced oxidation processes was performed. Fenton’s reagent with two different doses of hydrogen peroxide and iron and UV/H2O2 process was applied. The removal efficiency of biochemically oxidizable organic compounds (BOD5), chemically oxidizable compounds using potassium dichromate (CODCr) and nutrient (nitrogen and phosphorus) was examined. Studies have shown that the greatest degree of organic compounds removal expressed as a BOD5 index and CODCr index were obtained when Fenton’s reagent with greater dose of hydrogen peroxide was used - efficiency was respectively 72.0% and 69.8%. Moreover, in this case there was observed an increase in the value of ratio of BOD5/CODCr in treated leachate in comparison with raw leachate. Application of Fenton’s reagent for leachate treatment also allowed for more effective removal of nutrients in comparison with the UV/H2O2 process.

Przejdź do artykułu

Autorzy i Afiliacje

Barbara Pieczykolan
Izabela Płonka
Krzysztof Barbusiński
Magdalena Amalio-Kosel

Abstrakt

Odcieki ze składowisk odpadów komunalnych należy zaliczać do grupy silnie zanieczyszczonych ścieków przemysłowych. Wynika to z obecności w ich składzie różnych związków organicznych i nieorganicznych o wysokim stężeniu oraz toksycznych właściwościach. Istotne więc jest prawidłowe oczyszczanie odcieków przed odprowadzeniem do środowiska. Jedną z metod chemicznych wykorzystywanych do oczyszczania odcieków jest koagulacja. Podstawowym celem badań zaprezentowanych w niniejszej pracy było określenie wpływu koagulacji w połączeniu z sedymentacją na charakterystykę fizyczno-chemiczną i toksykologiczną odcieków pochodzących z jednego z wysypisk odpadów w Polsce. Badania koagulacji prowadzono w warunkach laboratoryjnych metodą ,jar-test'' używając w procesie chlorku poliglinu oraz chlorku żelazowego. Odcieki ,,surowe", jak również odcieki po koagulacji poddawano testom toksyczności z uwzględnieniem testu inhibicji wzrostu z glonami, trzech mikrobiotestów typu Toxkit z larwami skorupiaków, testu typu IQ Toxicity Test ze skorupiakami oraz testu LUM!Stox z bakteriami luminescencyjnymi. W przeprowadzonych badaniach ustalono, iż większą sprawnością technologiczną w usuwaniu związków organicznych z odcieków odznaczał się chlorek żelazowy (0,92 g Fe'•/ChZT usunięte) niż chlorek poliglinu ( 1,22 g AP•/ChZT usunięte). Dla optymalnych dawek koagulantów najkorzystniejsze efekty koagulacji osiągnięto przy pH = 6,5-6,8 dopasowywanym za pomocą NaOH. Koagulacja prowadzona w optymalnych warunkach pozwalała uzyskać zmniejszenie zawartości związków organicznych wyrażonych wartościami ChZT w granicach 40-84%. Ten efekt usunięcia związków organicznych z badanych odcieków nie wpłynął w znaczący sposób na zmniejszenie ich toksyczności. Z powyższych powodów proces koagulacji może być użyteczny jedynie jako jeden z elementów układu technologicznego oczyszczania odcieków z wysypisk odpadów komunalnych. Zastosowana w badaniach bateria testów wykazała swoją przydatność do oceny toksyczności odcieków o różnym stopniu ich zanieczyszczenia i na różnym etapie ich oczyszczania.
Przejdź do artykułu

Autorzy i Afiliacje

Jacek Wąsowski
Bożenna Słomczyńska
Tomasz Słomczyński

Abstrakt

These studies examined the concept of concentration and purification of several types of wastewater by freezing and thawing. The experiments demonstrated that freezing of contaminated liquid contributed to concentration of contaminants in solution as well as significant concentration and agglomeration of solid particles. A high degree of purification was achieved for many parameters. The results of comparative laboratory tests for single and multiple freezing are presented. It was found that there was a higher degree of concentration of pollutants in wastewater frozen as man-made snow than in bulk ice. Furthermore, the hypothesis that long storage time of liquid as snow and sufficient temperature gradient metamorphism allows for high efficiency of the concentration process was confirmed. It was reported that the first 30% of the melted liquid volume contained over 90% of all impurities. It gives great opportunities to use this method to concentrate pollutants. The results revealed that the application of this process in full scale is possible. Significant agglomeration of solid particles was also noted. Tests with clay slurry showed that repeated freezing and thawing processes significantly improve the characteristics of slurry for sedimentation and filtration.

Przejdź do artykułu

Autorzy i Afiliacje

Janusz A. Szpaczyński
Jeffrey A. White
Caroline L. Côté

Abstrakt

The Kalina pond has been well known as a severely degraded area in the Silesia region, Poland. The environmental deterioration results from high contamination of water and bottom sediments with recalcitrant and toxic organic compounds, mainly phenol. The study was aimed at developing a bioremediation-based approach suitable for this type of polluted areas, involving microbiological treatment of water as a key and integral part of other necessary actions: mechanical interventions and the use of physical methods. During the initial biological treatment stage, autochthonous microorganisms were isolated from contaminated samples of water, soil and sediment, then subjected to strong selective pressure by incubation with the pollutants, and finally, cultivated to form a specialised microbial consortium consisting of five extremophilic bacterial strains. Consortium propagation and its biodegradation activity were optimised under variant conditions enabling bacteria to proliferate and to obtain high biomass density at large volumes allowing for the in situ application. After installing aeration systems in the pond, the consortium was surface-sprinkled to launch bioremediation and then both bacterial frequency and the contaminant level was systematically monitored. The complex remediation strategy proved efficient and was implemented on an industrial scale enabling successful remedial of the affected site. Treatment with the specifically targeted and adapted microbial consortium allowed for removal of most organic pollutants within a four-month season of 2022: the chemical oxygen demand (COD) value decreased by 72%, polyaromatic hydrocarbon (PAH) level by 97%, while the content of total phenols and other monoaromatic hydrocarbons (BTEX) dropped below the detection thresholds.
Przejdź do artykułu

Autorzy i Afiliacje

Katarzyna Starzec
1
ORCID: ORCID
Emilia Stańkowska
2
Paulina Supel
1
ORCID: ORCID
Robert Mazur
3
ORCID: ORCID
Piotr Surma
2
Paweł Kaszycki
1
ORCID: ORCID

  1. University of Agriculture in Kraków, Faculty of Biotechnology and Horticulture, Department of Plant Biology and Biotechnology, al. Mickiewicza 21, 31-120 Kraków, Poland
  2. Remea Sp. z o. o., ul. Bonifraterska 17, 00-203 Warszawa, Poland
  3. AGH University of Science and Technology, Faculty of Mining Geodesy and Environmental Engineering, Department of Environmental Protection and Landscaping, al. Mickiewicza 30, 30-059 Kraków, Poland

Abstrakt

Artykuł przedstawia wyniki otrzymane podczas eksperymentów na sztucznych mokradłach, które były wybudowane oraz monitorowane na obrzeżu składowiska odpadów komunalnych na południu Polski. Mokradło miało złoże składające się ze żwiru oraz kamienia, na którym posadzono trzcinę, pałkę oraz wierzbę. Wykonano też poletko kontrolne bez roślinności. Każde poletko było zasilane kontrolowaną ilością odcieków ze składowiska odpadów. Pomiary jakości odcieków wykazywały bardzo wysokie stężenia szeregu wskaźników. W szczególności stwierdzano wysokie stężenia: BZT, ChZT, azotu oraz metali ciężkich. Ten wysoki poziom zanieczyszczeń był prawdopodobnie odpowiedzialny za wypadnie wierzby, której rośliny obumarły po upływie kilku miesięcy od posadzenia. Efektywność usuwania zanieczyszczeń mierzona jako obniżenie stężeń wybranych parametrów, dla czasów zatrzymania do 24 h wynosiła od O do 87%. Zauważono jednak, że efektywność usuwania zanieczyszczeń na poletku kontrolnym była tylko o kilka procent niższa niż na poletkach z roślinnością.
Przejdź do artykułu

Autorzy i Afiliacje

Włodzimierz A. Wójcik

Abstrakt

Landfilling is the main method of waste disposal in Poland as well as in most countries all over the world. Leachate originating during waste deposition may be a source of ground water pollution. The aim of the paper was to characterize and compare the composition of leachate originating from three landfills in Lublin Province (Poland) and differing in their methods of waste pre-treatment. Ozonation was used in the initial trials to treat landfill leachate. Experiments were carried out to determine whether ozonation using a single dose of 1.8 gO,lm3 has the same effect on the efficiency of organic removal from leachates characterized by different ages and degrees of solid waste pretreatment. From analyses (BOD5, COD, N-NH,, heavy metals) it was concluded, that excluding some fractions (glass, paper, plastics, aluminum, fine organic fraction) from the waste mass affects the leachate quality. The studied oxidizing method was found to influence the BOD5 and COD levels
Przejdź do artykułu

Autorzy i Afiliacje

Magdalena Lebiocka
Agnieszka Montusiewicz
Małgorzata Pawłowska
Janusz Ozonek
Ewa Szkutnik
Marcin Rosłan