Abstract

In the present paper it is proposed to consider the computer cooling capacity using the thermosyphon loop. A closed thermosyphon loop consists of combined two heaters and a cooler connected to each other by tubes. The first heater may be a CPU processor located on the motherboard of the personal computer. The second heater may be a chip of a graphic card placed perpendicular to the motherboard of personal computer. The cooler can be placed above the heaters on the computer chassis. The thermosyphon cooling system on the use of computer can be modeled using the rectangular thermosyphon loop with minichannels heated at the bottom horizontal side and the bottom vertical side and cooled at the upper vertical side. The riser and a downcomer connect these parts. A one-dimensional model of two-phase flow and heat transfer in a closed thermosyphon loop is based on mass, momentum, and energy balances in the evaporators, rising tube, condenser and the falling tube. The separate two-phase flow model is used in calculations. A numerical investigation for the analysis of the mass flux rate and heat transfer coefficient in the steady state has been accomplished.

Go to article

Authors and Affiliations

Jarosław Mikielewicz
Henryk Bieliński
Download PDF Download RIS Download Bibtex

Abstract

The current paper presents the experimental validation of the generalized model of the two-phase thermosyphon loop. The generalized model is based on mass, momentum, and energy balances in the evaporators, rising tube, condensers and the falling tube. The theoretical analysis and the experimental data have been obtained for a new designed variant. The variant refers to a thermosyphon loop with both minichannels and conventional tubes. The thermosyphon loop consists of an evaporator on the lower vertical section and a condenser on the upper vertical section. The one-dimensional homogeneous and separated two-phase flow models were used in calculations. The latest minichannel heat transfer correlations available in literature were applied. A numerical analysis of the volumetric flow rate in the steady-state has been done. The experiment was conducted on a specially designed test apparatus. Ultrapure water was used as a working fluid. The results show that the theoretical predictions are in good agreement with the measured volumetric flow rate at steady-state.

Go to article

Authors and Affiliations

Henryk Bieliński
Download PDF Download RIS Download Bibtex

Abstract

Clinker burning process has a decisive influence on energy consumption and the cost of cement production. A new problem is to use the process of decarbonization of alternative fuels from waste. These issues are particularly important in the introduction of a two-stage combustion of fuel in a rotary kiln without the typical reactor-decarbonizator. This work presents results of numerical studies on thermal-hydraulic phenomena in the riser chamber, which will be designed to burn fuel in the system where combustion air is supplied separately from the clinker cooler. The mathematical model is based on a combination of two methods of motion description: Euler description for the gas phase and Lagrange description for particles. Heat transfer between particles of raw material and gas was added to the numerical calculations. The main aim of the research was finding the correct fractional distribution of particles. For assumed particle distribution on the first stage of work, authors noted that all particles were carried away by the upper outlet to the preheater tower, what is not corresponding to the results of experimental studies. The obtained results of calculations can be the basis for further optimization of the design and operating conditions in the riser chamber with the implementation of the system.

Go to article

Authors and Affiliations

Grzegorz Borsuk
Bolesław Dobrowolski
Grzegorz Nowosielski
Jacek Wydrych
Jerzy Duda
Download PDF Download RIS Download Bibtex

Abstract

This paper focuses on the computer cooling capacity using the thermosyphon loop with minichannels and minipump. The one-dimensional separate model of two-phase flow and heat transfer in a closed thermosyphon loop with minichannels and minipump has been used in calculations. The latest correlations for minichannels available in literature have been applied. This model is based on mass, momentum, and energy balances in the evaporator, rising tube, condenser and the falling tube. A numerical analysis of the mass flux and heat transfer coefficient in the steady state has been presented.

Go to article

Authors and Affiliations

Jarosław Mikielewicz
Henryk Bieliński
Download PDF Download RIS Download Bibtex

Abstract

The study presents the possible use of optoelectronic system for the measurement of values specific for hydrodynamics of two-phase gas very-high-viscosity liquid flow in vertical pipes. An experimental method was provided, and the findings were presented and analysed for selected values which characterise the two-phase flow.

Go to article

Authors and Affiliations

Krystian Czernek
Stanisław Witczak
Download PDF Download RIS Download Bibtex

Abstract

An experimental study was conducted in order to investigate two-phase flow regimes and fully developed pressure drop in a mini-size, horizontal rectangular channel. The test section was machined in the form of an impacting tee junction in an acrylic block (in order to facilitate visualization) with a rectangular cross-section of 1.87-mm height on 20-mm width on the inlet and outlet sides. Pressure drop measurement and flow regime identification were performed on all three sides of the junction. Air-water mixtures at 200 kPa (abs) and room temperature were used as the test fluids. Four flow regimes were identified visually: bubbly, plug, churn, and annular over the ranges of gas and liquid superficial velocities of 0.04 ≤ JG ≤ 10 m/s and 0.02 ≤ JL ≤ 0.7 m/s, respectively, and a flow regime map was developed. Accuracy of the pressure-measurement technique was validated with single-phase, laminar and turbulent, fully developed data. Two-phase experiments were conducted for eight different inlet conditions and various mass splits at the junction. Comparisons were conducted between the present data and former correlations for the fully developed two-phase pressure drop in rectangular channels with similar sizes. Wide deviations were found among these correlations, and the correlations that agreed best with the present data were identified.
Go to article

Authors and Affiliations

Amr Mohamed Elazhary
Hassan M. Soliman
Download PDF Download RIS Download Bibtex

Abstract

In the paper a method developed earlier by authors is applied to calculations of pressure drop and heat transfer coefficient for flow boiling and also flow condensation for some recent data collected from literature for such fluids as R404a, R600a, R290, R32,R134a, R1234yf and other. The modification of interface shear stresses between flow boiling and flow condensation in annular flow structure are considered through incorporation of the so called blowing parameter. The shear stress between vapor phase and liquid phase is generally a function of nonisothermal effects. The mechanism of modification of shear stresses at the vapor-liquid interface has been presented in detail. In case of annular flow it contributes to thickening and thinning of the liquid film, which corresponds to condensation and boiling respectively. There is also a different influence of heat flux on the modification of shear stress in the bubbly flow structure, where it affects bubble nucleation. In that case the effect of applied heat flux is considered. As a result a modified form of the two-phase flow multiplier is obtained, in which the nonadiabatic effect is clearly pronounced.

Go to article

Authors and Affiliations

Dariusz Mikielewicz
Jarosław Mikielewicz
Rafał Andrzejczyk
Blanka Jakubowska
Download PDF Download RIS Download Bibtex

Abstract

Gas-liquid two-phase flow in minichannels has been the subject of increased research interest in the past few years. Evaluation, however, of today's state of the art regarding hydrodynamics of flow in minichannels shows significant differences between existing test results. In the literature there is no clear information regarding: defining the boundary between minichannels and conventional channels, labelling of flow patterns. The review of literature on the hydrodynamics of gas-liquid flow in minichannels shows that, despite the fact that many research works have been published, the problem of determining the effect of diameter of the minichannel on the hydrodynamics of the flow is still at an early stage. Therefore, the paper presents the results of research concerning determination of flow regime map for the vertical upward flow in minichannels. The research is based on a comprehensive analysis of the literature data and on the research that has been carried out. Such approach to the mentioned above problems concerning key issues of the two-phase flow in minichannels allowed to determine ranges of occurrence of flow structures with a relatively high accuracy.

Go to article

Authors and Affiliations

Monika Wengel
Barbara Miłaszewicz
Roman Ulbrich
Download PDF Download RIS Download Bibtex

Abstract

Technology advancements entail a necessity to remove huge amounts of heat produced by today’s electronic devices based on highly integrated circuits, major generators of heat. Heat transfer to boiling liquid flowing through narrow minichannels is a modern solution to the problem of heat transfer enhancement. The study was conducted for FC-72 boiling in a rectangular, vertical and asymmetrically heated minichannel that had depths of 0.5-1.5 mm, a width of 20 mm and a length of 360 mm. The heat flux increased and decreased within the range of 58.3-132.0 kWm−2, the absolute pressure ranged from 0.116 to 0.184 MPa and the mass flux was 185-1139.2 kgm−2s−1. The boiling process took place on a flat vertical heating surface made of Haynes-230 0.1 mm thick acid-proof rolled plate with the surface roughness of 121 μm.

Go to article

Authors and Affiliations

Robert Kaniowski
Mieczysław Poniewski
Download PDF Download RIS Download Bibtex

Abstract

An approach – relaying on application of nanofluid as a working fluid, to improve performance of the two-phase thermosyphon heat exchanger (TPTHEx) has been proposed. The prototype heat exchanger consists of two horizontal cylindrical vessels connected by two risers and a downcomer. Tube bundles placed in the lower and upper cylinders work as an evaporator and a condenser, respectively. Distilled water and nanofluid water-Al2O3solution were used as working fluids. Nanoparticles were tested at the concentration of 0.01% and 0.1% by weight. A modified Peclet equation and Wilson method were used to estimate the overall heat transfer coefficient of the tested TPTHEx. The obtained results indicate better performance of the TPTHEx with nanofluids as working fluid compared to distilled water, independent of nanoparticle concentration tested. However, increase in nanoparticle concentration results in overall heat transfer coefficient decrease of the TPTHEx examined. It has been observed that, independent of nanoparticle concentration tested, decrease in operating pressure results in evaporation heat transfer coefficient increase.

Go to article

Authors and Affiliations

Janusz T. Cieśliński
Download PDF Download RIS Download Bibtex

Abstract

Paper deals with theoretical analysis of possible efficiency increase of compression refrigeration cycles by means of application of a twophase ejector. Application of the two phase ejector in subcritical refrigeration system as a booster compressor is discussed in the paper. Results of exergy analysis of the system operating with various working fluids for various operating conditions have been shown. Analysis showed possible exergy efficiency increase of refrigeration compression cycle.

Go to article

Authors and Affiliations

Jarosław Karwacki
Adam Dudar
Dariusz Butrymowicz
Kamil Śmierciew
Download PDF Download RIS Download Bibtex

Abstract

The aim of the study was the implementation of a numerical simulation of the air-water two-phase flow in the minichannel and comparing results obtained with the values obtained experimentally. To perform the numerical simulations commercial software ANSYS FLUENT 12 was used. The first step of the study was to reproduce the actual research installation as a three-dimensional model with appropriate and possible simplifications - future computational domain. The next step was discretisation of the computational domain and determination of the types of boundary conditions. ANSYS FLUENT 12 has three built-in basic models with which a two-phase flow can be described. However, in this work Volume-of-Fluid (VOF) model was selected as it meets the established requirements of research. Preliminary calculations were performed for a simplified geometry. The calculations were later verified whether or not the simplifications of geometry were chosen correctly and if they affected the calculation. The next stage was validation of the chosen model. After positive verification, a series of calculations was performed, in which the boundary conditions were the same as the starting conditions in laboratory experiments. A satisfactory description of the experimental data accuracy was attained.

Go to article

Authors and Affiliations

Jarosław Sowiński
Marek Krawczyk
Marek Dziubiński
Download PDF Download RIS Download Bibtex

Abstract

An optical tomograph in which a tested object is illuminated from five directions has been presented in the paper. The measurements of luminous intensity after changing into discrete signals (0 or 1) in the detectors equipped with 64 optical sensors were subjected to reconstruction by means of the matrix algorithm. Detailed description of the measuring sensor, as well as the principles of operation of the electronic system, has been given in the paper. Optical phenomena occurring at the phase boundary while transmitted through the sensor wall and phenomena inside the measuring space have also been taken into account. The method of the sensor calibration has been analysed and a way of technical solution of the problem under consideration has been discussed. The elaborated method has been tested using objects of the known shape and dimensions. It was found that reconstruction of the shapes of moving bubbles and determination of their main parameters is also possible with a reasonable accuracy.

Go to article

Authors and Affiliations

Mariusz R. Rząsa
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the analysis of results of the investigations concerning a vertical pipe submersion coefficient h/L with an air-water mixer of the described type. The investigations were performed on an air lift pump testing stand, constructed in a laboratory on a scale of 1:1. At first, the paper presents the possibilities of application of air lift pumps. The investigations to date have been briefly characterized and a research problem formulated. Then the paper describes the construction and working principle of the air lift pump testing stand, constructed in a laboratory. It presents the methodology of derivation of empirical formulas for calculation of vertical pipe submersion coefficients h/L. The comparative analysis of the values of h/L determined in the measurements with the values of h/L calculated using the derived empirical formulas was carried out. The research scope encompassed the derivation of the aforementioned empirical formulas for five fixed values of air lift pump delivery head H, comparison of the obtained values h/L determined in the measurements with the values of h/L calculated using the derived empirical formulas and the improved analytical Stenning-Martin model. To derive the empirical formulas for calculation of the vertical pipe submersion coefficient h/L, the dimensional analysis and multiple regression was applied. The investigations of the vertical pipe submersion coefficient h/L were carried out for the vertical pipe internal diameter d = 0.04 m and for the fixed delivery heads H: 0.45, 0.90, 1.35, 1.80, 2.25 m. The values calculated using the derived empirical formulas (23), (24), (25), (26), (27) coincide with the values of h/L determined in the measurements for the whole range of the investigated delivery heads H. On the other hand, the values of h/L calculated using the improved analytical Stenning-Martin model do not coincide with the values of h/L determined in the measurements for the delivery heads H equal 0.45 and 0.90 m, whereas they are comparable for H equal 1.35, 1.80, 2.25 m. For the tested air lift pump with the air-water mixer of the described type (Fig. 2), the maximum air pressure should not exceed pp = 145 kPa, because for higher pressures the water flow rate diminishes. In the air lift pump being tested, the water flow rate Qw grows along with the rise in the air flow rate and in the vertical pipe submersion coefficient h/L whereas falls along with the rise in the delivery head H.
Go to article

Authors and Affiliations

M. Kalenik
M. Chalecki
P. Wichowski
A. Kozioł
M. Babych
Download PDF Download RIS Download Bibtex

Abstract

Performance assessment of ejector-expansion vapor compression refrigeration system with eco-friendly R134a alternative refrigerants (R152a, R1234yf, R600a, R600, R290, R161, R32, and propylene) is presented for air-conditioning application. Ejector has been modeled by considering experimental data based correlations of component efficiencies to take care of all irreversibilities. Ejector area ratio has been optimized based on maximum coefficient of performance (COP) for typical air-conditioner operating temperatures. Selected refrigerants have been compared based on area ratio, pressure lift ratio, entrainment ratio, COP, COP improvement and volumetric cooling capacity. Effects of normal boiling point and critical point on the performances have been studied as well. Using ejector as an expansion device, maximum improvement in COP is noted in R1234yf (10.1%), which reduces the COP deviation with R134a (4.5% less in basic cycle and 2.5% less in ejector cycle). Hence, R1234yf seems to be best alternative for ejector expansion system due to its mild flammability and comparable volumetric capacity and cooling COP. refrigerant R161 is superior to R134a in terms of both COP and volumetric cooling capacity, although may be restricted for low capacity application due to its flammability.

Słowa kluczowe

Go to article

Authors and Affiliations

Shubham Mishra
Jahar Sarkar
Download PDF Download RIS Download Bibtex

Abstract

This paper presents the results of studies in two phase gasliquid flow around tube bundle in the model of shell tube heat exchanger. Experimental investigations of heat transfer coefficient on the tubes surface were performed with the aid of electrochemical technique. Chilton-Colburn analogy between heat and mass transfer was used. Twelve nickel cathodes were mounted on the outside surface of one of the tubes. Measurement of limiting currents in the cathodic reduction of ferricyanide ions on nickel electrodes in aqueous solution of equimolar quantities of K3Fe(CN)6and K4Fe(CN)6in the presence of NaOH basic solution were applied to determine the mass transfer coefficient. Controlled diffusion from ions at the electrode was observed and limiting current plateau was measured. Measurements were performed with data acquisition equipment controlled by software created for this experiment. Mass transfer coefficient was calculated on the basis of the limiting current measurements. Results of mass transfer experiments (mass transfer coefficient) were recalculated to heat transfer coefficient. During the experiments, simultaneously conducted was the the investigation of two-phase flow structures around tubes with the use of digital particle image velocimetry. Average velocity fields around tubes were created with the use of a number of flow images and compared with the results of heat transfer coefficient calculations.

Go to article

Authors and Affiliations

Daniel Zając
Marcin Karaś
Roman Ulbrich
Download PDF Download RIS Download Bibtex

Abstract

In this study, the influences of different parameters at performance two-phase closed thermosiphon (TPCT) was presented. It has been confirmed that the working fluid, as well as operating parameters and fill ratio, are very important factors in the performance of TPCT. The article shows characteristics of gravitational tube geometries, as well as the technical characteristic of the most important system components, i.e., the evaporator/condenser. The experiment’s plan and the results of it for the two-phase thermosiphon for both evaluated geometries with varying thermal and fluid flow parameters are presented. Experiments were performed for the most perspective working fluids, namely: water, R134a, SES36, ethanol and HFE7100. Obtained research proves the possibility to use TPCT for heat recovery from the industrial waste water.

Go to article

Authors and Affiliations

Rafał Andrzejczyk
Tomasz Muszyński
Download PDF Download RIS Download Bibtex

Abstract

The article presents detailed two-phase adiabatic pressure drops data for refrigerant R134a. Study cases have been set for a mass flux varying from 200 to 400 kg/m2s, at the saturation temperature of 19.4°C. Obtained experimental data was compared with the available correlations from the literature for the frictional pressure drop during adiabatic flow. Influence of mixture preparation on pressure drop was investigated, for varying inlet subcooling temperature in the heated section. The flow patterns have also been obtained by means of a high-speed camera placed in the visualization section and compared with literature observations.

Go to article

Authors and Affiliations

Tomasz Muszyński
Rafał Andrzejczyk
Carlos A. Dorao
Download PDF Download RIS Download Bibtex

Abstract

High heat flux removal are important issue in many perspective applications such as computer chips, laser diode arrays, or boilers working on supercritical parameters. Electronic microchips constructed nowadays are model example of high heat flux removal, where the cooling system have to maintain the temperature below 358 K and take heat flux up to 300 W/cm2. One of the most efficient methods of microchips cooling turns out to be the spray cooling method. Review of installations has been accomplished for removal at high heat flux with liquid sprays. In the article are shown high flux removal characteristic and dependences, boiling critical parameters, as also the numerical method of spray cooling analysis.

Go to article

Authors and Affiliations

Przemysław Smakulski
Download PDF Download RIS Download Bibtex

Abstract

The application of aqueous two-phase systems (ATPS) is a cost-effective and simple method of protein separation (including enzymes) from complex systems. The first stage of designing the protein purification process in an ATPS involves the identification of the conditions for the formation of a given extraction system. For this purpose, the conditions for the formation of ATPSs in a thermoseparating EO50PO50 polymer/potassium phosphates system have been studied. Factors determining the ATPS formation comprised: separation temperature (4ºC or 20ºC), phosphate solution pH (6, 7.5 or 9) as well as the concentration of NaCl introduced into the systems (0.085 M, 0.475 M and 0.85 M). ATPS without NaCl were prepared as well. The conditions for the formation of the primary EO50PO50/potassium phosphate ATPS were determined with their phase diagrams. It was observed that with an increase of phosphate pH and NaCl concentration in the system, there was a decrease of the EO50PO50 and phosphate concentrations necessary to form a primary ATPS. After the primary two-phase separation, the top phase (rich in the EO50PO50 polymer) was partitioned from the bottom phase (rich in phosphates). Next, by means of polymer phase thermoseparation, a secondary two-phase system was formed. In the secondary EO50PO50/phosphate ATPS, the bottom phase was formed by the concentrated EO50PO50 polymer (30-80% concentration), while the top phase by a solution composed mainly of water, containing phosphate ions and remains of EO50PO50 polymer (3-7%).

Go to article

Authors and Affiliations

Radosław Dembczyński
Wojciech Białas
Tomasz Jankowski
Download PDF Download RIS Download Bibtex

Abstract

Cu–4.7 wt. % Sn alloy wire with Ø10 mm was prepared by two-phase zone continuous casting technology, and the temperature field, heat

and fluid flow were investigated by the numerical simulated method. As the melting temperature, mold temperature, continuous casting

speed and cooling water temperature is 1200 °C, 1040 °C, 20 mm/min and 18 °C, respectively, the alloy temperature in the mold is in the

range of 720 °C–1081 °C, and the solid/liquid interface is in the mold. In the center of the mold, the heat flow direction is vertically

downward. At the upper wall of the mold, the heat flow direction is obliquely downward and deflects toward the mold, and at the lower

wall of the mold, the heat flow deflects toward the alloy. There is a complex circular flow in the mold. Liquid alloy flows downward along

the wall of the mold and flows upward in the center.

Go to article

Authors and Affiliations

J. Luo
X. Liu
X. Wang
Download PDF Download RIS Download Bibtex

Abstract

The void fraction is one of the most important parameters characterizing a multiphase flow. The prediction of the performance of any system operating with more than single phase relies on our knowledge and ability to measure the void fraction. In this work, a validated simulation study was performed in order to predict the void fraction independent of the flow pattern in gas-liquid two-phase flows using a gamma ray 60Co source and just one scintillation detector with the help of an artificial neural network (ANN) model of radial basis function (RBF). Three used inputs of ANN include a registered count under Compton continuum and counts under full energy peaks of 1173 and 1333 keV. The output is a void fraction percentage. Applying this methodology, the percentage of void fraction independent of the flow pattern of a gas-liquid two-phase flow was estimated with a mean relative error less than 1.17%. Although the error obtained in this study is almost close to those obtained in other similar works, only one detector was used, while in the previous studies at least two detectors were employed. Advantages of using fewer detectors are: cost reduction and system simplification.
Go to article

Authors and Affiliations

Roshani Gholam H.
Nazemi Ehsan
Shama Farzin
Imani Mohammad A.
Mohammadi Salar
Download PDF Download RIS Download Bibtex

Abstract

To find effective and practical methods to distinguish gas-liquid two-phase flow patterns, new flow pattern maps are established using the differential pressure through a classical Venturi tube. The differential pressure signal was first decomposed adaptively into a series of intrinsic mode functions (IMFs) by the ensemble empirical mode decomposition. Hilbert marginal spectra of the IMFs showed that the flow patterns are related to the amplitude of the pressure fluctuation. The cross-correlation method was employed to sift the characteristic IMF, and then the energy ratio of the characteristic IMF to the raw signal was proposed to construct flow pattern maps with the volumetric void fraction and with the two-phase Reynolds number, respectively. The identification rates of these two maps are verified to be 91.18% and 92.65%. This approach provides a cost-effective solution to the difficult problem of identifying gas-liquid flow patterns in the industrial field.

Go to article

Authors and Affiliations

Zhiqiang Sun
Luyang Chen
Fengyan Yao