Abstract

The paper presents an analysis of the behaviour of bent reinforced concrete beams strengthened with CFRP laminates fixed with adhesive before and after unloading, and more importantly, an analysis of the work of reinforced concrete beams strengthened with pre-stressed CFRP laminates fixed with adhesive. The analyses were based on a moment-curvature model prepared by the author for reinforced concrete beams strengthened under load with pre-stressed CFRP laminates. The model was used to determine the effect of compression with CFRP laminates and their mechanical properties on the effectiveness of strengthening the reinforced concrete beams analysed in this study.

Go to article

Authors and Affiliations

J. Korentz
Download PDF Download RIS Download Bibtex

Abstract

The concrete deck at the negative bending moment region of a continuous steel-concrete composite girder bridge is the weakest part of the structure. Introducing ultra-high performance concrete (UHPC) to the hogging region may overcome the shortage and break through the bottleneck. This paper explores the cracking performance of steel-concrete composite girders with concrete slabs topped by a thin layer of UHPC subjected to a negative bending moment.Areal continuous composite girder bridge is briefly introduced as the engineering background, and the cracking characteristic of the concrete deck over the middle piers of the bridge is numerically modeled. Approaches to strengthen the cracking performance of the concrete deck at the hogging region through topping UHPC overlays are proposed. The effectiveness of the approaches is examined by conducting a series of numerical and experimental tests. Numerical results indicate that the normal concrete (NC) deck near the middle forums of the bridge would crack due to the large tensile stress from negative bending moments. Replacing the top concrete with an identical-thick UHPC overlay can increase the cracking resistance of the deck under the moment. As the thickness of the UHPC overlay increased from 6.0 cm to 12.0 cm, the maximum shear stress at the UHPC overlay-to-NC substrate interface under different load combinations was decreased by 56.3%~65.3%. Experimental results show that the first-cracking load of the composite beam usingan NC-UHPC overlaid slab was 2.1 times that using an NC slab. The application of a UHPC overlaid
deck can significantly improve the crack performance of the steel-concrete composite girder bridge.
Go to article

Authors and Affiliations

Zhiyong Wan
1 2
ORCID: ORCID
Guohe Guo
3
ORCID: ORCID
Zhiguo Wang
3
ORCID: ORCID
Shaohua He
4
ORCID: ORCID
Juliang Tan
2
ORCID: ORCID
Libo Hou
5
ORCID: ORCID

  1. College of Civil Engineering, Hunan University, Changsha 410082, China
  2. Guangdong Communication Planning & Design Institute Co., Ltd., Guangzhou 510507, China
  3. Guangdong Yunmao Expressway Co. Ltd., Guangzhou 525346, China
  4. Guangdong University of Technology, Guangzhou 510006, China
  5. Guangdong Highway Construction Co., LTD, Guangzhou 510623, China