This paper presents an experimental study on influence of input light polarization on the spectral characteristics of a fibre twist sensor based on Tilted Fiber Bragg Grating (TFBG) with simultaneous application of bending to an optical fibre. The application of proposed measurement stand could provide the ability of transforming the bending to a displacement. The twist measurement was performed by tuning of the sensor illuminating light polarization angle. The spectral parameters of selected cladding mode which are sensitive to the rotation of input light polarization angle have been shown. This paper shows the characteristics of transmittivity and wavelength shift for an incident high-order cladding mode measured with different curvatures of fibre. The dependency of selected cladding mode spectral parameters related with the twist measurement on the influence of temporary bending has been shown. The measurements were performed for two positions of sensing structure refractive index perturbations in relation to the bending direction plane. The experimental results show that the direction of TFBG structure bending has a small influence on the stability of spectral parameters characteristic for twist measurement, assuming that the bending direction is fixed while measurement.
In this paper, we present a synthesis of the parameters of the fiber Bragg grating (FBG) and the reconstruction of the distributed strain affecting the grating, performed by means of its reflection spectrum. For this purpose, we applied the transition matrix method and the Nelder-Mead nonlinear optimization method. Reconstruction results of the strain profile carried out on the basis of a simulated reflection spectrum as well as measured reflection spectrum of the FBG indicate good agreement with the original strain profile; the profile reconstruction errors are within the single digit percentage range. We can conclude that the Nelder-Mead optimization method combined with the transition matrix method can be used for distributed sensing problems.
As part of the work, the error level of simulations of uniform optical-fibre Bragg gratings was determined using the transitionmatrixmethod. The errorswere established by comparing the transmission characteristics of the structures obtained by simulation with the corresponding characteristics arrived at experimentally. To compile these objects, elementary properties of the characteristics were specified, also affecting the applications of Bragg gratings, and compared with each other. The level of error in determining each of these features was estimated. Relationships were also found between the size of the physical properties of Bragg gratings and the level of errors obtained. Based on the findings, the correctness of the simulation of structures with the said method was verified, giving satisfying results.
Dynamic angle measurement (DAM) plays an important role in precision machining, aerospace, military and artificial intelligence. Because of its advantages including high sensitivity, solid state and miniaturization, fibre-optic gyroscope (FOG) has great application prospects in the field of DAM. In this paper, we propose a dynamic angle metrology method based on FOG and a rotary table to evaluate the DAMaccuracy with FOG. The system synchronously collects data from the FOG and rotary table, and analyses the DAM accuracy of the FOG for different sway conditions compared with that of the angle obtained from the rotary table. An angle encoder in the rotary table provides absolute or incremental angular displacement output with angular displacement measurement accuracy of 10′′ (0:0028◦) and angular displacement repeat positioning accuracy of 3′′ (0:00083◦), and can be used as an angle reference. The experimental results show that the DAM accuracy of the FOG is better than 0:0028◦ obtained with the angular encoder, and the absolute DAM accuracy of the FOG is better than 0:0048◦ for given conditions. At the same time, for the multi-path signal synchronization problem in the metrology field, this paper proposes a signal delay measurement method combining test and algorithm procedures, which can control a delay within 25 μs.
In this article, we study tilted fiber Bragg gratings (TFBGs) with tilt angles of 6◦ and 8◦, their transmission spectra, and spectral parameters that have a linear dependence on the refractive index of the environment. It is shown that there can be several such characteristics, such as the minimum, width and energy of the spectrum. The linear dependence of the spectrum width on the refractive index does not depend on the tilt angle. The linear dependence of the spectrum minimum is only observed for a tilt angle of 8◦. The results of this work can be used to create a sensor system based on an optical fiber.
In this work, an electrically tunable long-period fiber grating (LPFG) coated with liquid crystal layer (LC) is presented. As a LC layer, a prototype low-birefringence 1550A LC mixture was chosen. As a LPFG host, two types of gratings were studied: the LPFGs based on a standard telecommunication fiber, produced by an electric arc technique with a period of 222 μm, and the LPFGs based on a boron co-doped fiber written by a UV technique with a period of 226.8 μm. The relatively short period of these gratings allowed exploiting unique sensing properties of the attenuation bands associated with modes close to the turn-around point. Experiments carried out showed that for the UV-induced LPFG with a LC layer, on the powered state the attenuation band could be offset from the attenuation band measured in the unpowered state by almost 130 nm. When the arc-induced LPFG was coated with the LC, the depth of the attenuation band could be efficiently controlled by applying an external E-field. Additionally, all experimental results obtained in this work were supported by the theoretical analysis based on a model developed with Optigrating v.4.2 software.
This paper presents the implementation of a thinned fibre Bragg grating as a fuel adulteration sensor for volatile organic compounds. The proposed sensor can detect upto 10% adulteration of benzene, toluene and xylene: hydrocarbons precisely, whereas traditional methods can detect only upto 20% adulteration. The results obtained from the experiments are verified using Finite Difference Time Domain method. It is found that experimental results have very less deviation from simulation results. The proposed sensor provides us with the new possibility that may have commercial application, as well.
Monitoring the stress change of bolt and knowing the anchoring condition in a reasonable and effective way, accurately, can effectively prevent tunnel accident from breaking out. The stress of rock mass around the roadway is usually transferred to the anchor rod in the form of axial load, so it is of great significance to study the axial load of the bolt. In this paper, a full size anchoring and drawing experiment system was designed and established, innovatively, which realized the pull-out test of 2.5 m prestressed end Anchorage and the full-length Anchorage by using the new resin anchorage agent under vertical and horizontal loads. Through the application of fiber Bragg grating (FBG) sensing technology to the test of full-scale anchor rod, the axial force distribution characteristics of the end Anchorage and the full-length Anchorage anchor rod were obtained under the action of pre-tightening torque and confining rock pressure. The comparison indicates that the proportion of high stress range accounts for only 17.5% and the main bearing range is near the thread end of anchor rod, the proportion of main bearing range of end Anchorage is 83.3%, and the feasibility of FBG force-measuring anchor rod is verified in the field. The research results have certain reference value.
The contradiction between the restriction of grating manufacturing technology and high-resolution measurement requirements has been the focus of attention. The precision requirement of angle calculation during the digital subdivision processing of a Moiré signal is focused on, the causes of errors in the solution of arcsine function are analysed, and an improved coordinate rotation digital computer (CORDIC)with double-rotation iteration is proposed by discussing the principle of the conventional CORDIC in detail herein. Because the iterative number and data width of the improved CORDIC are limited by the finite digital circuit resources and thus determine the calculation accuracy directly, subsequently the overall quantization error (OQE) of the improved CORDIC is analysed. The approximate error and rounding error of the algorithm are deduced, and the error models of iterative number and data width are established. The validity and application value of the improved CORDIC are proved through simulations and experiments involving a subdividing circuit. The corresponding relation between the approximate error, rounding error and iteration number, as well as the bit width are proved by quantization. The error of subdivision with the improved CORDIC, obtained through a calibration experiment, is within ±0.5′′ and the mean variance is 0.2′′. The results of the research can be applied directly to a digital subdivision system to guide the parameter setting in the iterative process, which is of crucial importance in the quantitative analysis of error separation and error synthesis.
Spectral characteristics and amplitude tunability of a long period grating with a dual- resonance inside fiber loop mirror are studied in terms of applied stress caused by elongation. Inserting the polarization controller between grating and part of polarization maintaining fiber in the loop structure enables tuning of resonance and interferometric peaks. The maximum sensitivity of demonstrated sensor is of 1.943 dB/mε for the range of 1.1–4.4 mε. Combination of these two optical components allows to measure strain in a wider range comparing with sensors based on standard long period grating.
An interferometric structure based on a Dual-Resonance Long-Period Grating (DRLPG) within a Fiber Loop Mirror (FLM) is presented in this paper. Its purpose is to measure the refractive index (RI) of liquid analytes. The grating is the RI sensing probe, while the FLM serves as a band-pass filter. Due to the high extinction ratio of the FLM, amplitude measurements can be obtained, allowing implementation of the differential interrogation method to establish the sensitivity of the device. The use of a polarization controller makes it possible to fine-tune the interferometric peaks with respect to the two notches of the DRLPG. Precisely aligned configuration produces a maximum sensitivity of 3871.5 dB/RIU within the RI range of 1.3333 up to 1.3419 with linear sensor response.
The Fibre Bragg Grating (FBG) based temperature optical sensor has been designed and demonstrated. FBGs have been modelled and fabricated so as to convert the Bragg wavelength shift into the intensity domain. The main experimental setup consists of a filtering FBG and two scanning FBGs, respectively, left and right scanning FBG, whereby scanning FBGs are symmetrically located on the slopes of the filtering FBG. Such an approach allows for the modulation of power for the propagating optical signal depending on the ambient temperature at the scanning FBG location. A positive or negative change of power is determined by the spectral response of the FBG. Experimental research of the scanning FBGs’ sensitivities emphasized that the key issue is the filtering FBG. A different level of sensitivity could be achieved due to the spectral characteristic of the filtering FBG. Omitting advanced and high-cost devices, the FBG-based temperature sensor is presented. The FBG-based sensor setup could yield resolution of 1°C for the range of temperature 0.5°C to 52.5°C. The experimental study has been performed as a base for an easy-placed sensor system to monitor external parameters in real environment.