An original method of skeletal system modelling is presented in detail. Using DICOM images obtained from CT and PET tests, shell models of nine bones were created (humerus, radius, ulna, scapula, clavicle, femur, tibia, fibula, pelvis). Two methods of bone behaviour are also proposed, the first method treating the bone as a solid structure and the second method treating the bone as a complex porous structure. The behaviour of model parts is numerically examined by using the finite element method.
A new approach to passive electromagnetic modelling of coupled–cavity quantum cascade lasers is presented in this paper. One of challenges in the rigorous analysis of such eigenvalue problem is its large size as compared to wavelength and a high quality factor, which prompts for substantial computational efforts. For those reasons, it is proposed in this paper to consider such a coupled-cavity Fabry-Perot resonant structure with partially transparent mirrors as a two-port network, which can be considered as a deterministic problem. Thanks to such a novel approach, passive analysis of an electrically long laser can be split into a cascade of relatively short sections having low quality factor, thus, substantially speeding up rigorous electromagnetic analysis of the whole quantum cascade laser. The proposed method allows to determine unequivocally resonant frequencies of the structure and the corresponding spectrum of a threshold gain. Eventually, the proposed method is used to elaborate basic synthesis rules of coupled–cavity quantum cascade lasers.
Image-guided High Intensity Focused Ultrasound (HIFU) technique is dynamically developing technology for treating solid tumors due to its non-invasive nature. Before a HIFU ablation system is ready for use, the exposure parameters of the HIFU beam capable of destroying the treated tissue without damaging the surrounding tissues should be selected to ensure the safety of therapy. The purpose of this work was to select the threshold acoustic power as well as the step and rate of movement of the HIFU beam, generated by a transducer intended to be used in the HIFU ablation system being developed, by using an array of thermocouples and numerical simulations. For experiments a bowl-shaped 64-mm, 1.05 MHz HIFU transducer with a 62.6 mm focal length (f-number 0.98) generated pulsed waves propagating in two-layer media: water/ex vivo pork loin tissue (50 mm/40 mm) was used. To determine a threshold power of the HIFU beam capable of creating the necrotic lesion in a small volume within the tested tissue during less than 3 s each tissue sample was sonicated by multiple parallel HIFU beams of different acoustic power focused at a depth of 12.6 mm below the tissue surface. Location of the maximum heating as well as the relaxation time of the tested tissue were determined from temperature variations recorded during and after sonication by five thermo-couples placed along the acoustic axis of each HIFU beam as well as from numerical simulations. The obtained results enabled to assess the location of each necrotic lesion as well as to determine the step and rate of the HIFU beam movement. The location and extent of the necrotic lesions created was verified using ultrasound images of tissue after sonication and visual inspection after cutting the samples. The threshold acoustic power of the HIFU beam capable of creating the local necrotic lesion in the tested tissue within 3 s without damaging of surrounding tissues was found to be 24 W, and the pause between sonications was found to be more than 40 s.
The aim of this study was to evaluate the hearing status of call centre operators in relation to their noise exposure. Conventional pure-tone audiometry and extended high-frequency audiometry were performed in 49 workers, aged 22–47 years (mean ± SD: 32.0 ± 6.0 years), working in call centre from 1.0 to 16.5 years (mean ± SD: 4.7 ± 2.9 years).
Questionnaire inquiry aimed at collecting personal data, the information on ommunication headset usage habits, self-assessment of hearing ability and identification of risk factors for noise-induced hearing loss were also carried out. Sound pressure levels generated by the communication headset were determined using the artificial ear technique specified in CSA Z107.56-13 (2013) standard. The background noise prevailing in offices was also measured according to PN-N-01307 (1994) and PN-EN ISO 9612 (2011).
Personal daily noise exposure levels in call centre operators varied from 66 to 86 dB (10–90th percentile). About half of the study subjects had normal hearing in the standard frequencies (from 250 to 8000 Hz) in both ears, while only 27.1% in the extended high-frequencies (9–16 kHz). Moreover, both high-frequency and speech-frequency hearing losses were observed in less than 10% of audiograms, while the extended high-frequency threshold shift was noted in 37.1% of analysed ears. The hearing threshold
levels of call centre operators in the frequency of 0.25–11.2 kHz were higher (worse) than the expected median values for equivalent (due to age and gender) highly screened population specified in ISO 7029 (2017). Furthermore, they were also higher than predicted for 500–4000 Hz according to ISO 1999 (2013) based on the results of noise exposure evaluation.
A novel dual mode logic (DML) model has a superior energy-performance compare to CMOS logic. The DML model has unique feature that allows switching between both modes of operation as per the real-time system requirements. The DML functions in two dissimilar modes (static and dynamic) of operation with its specific features, to selectively obtain either low-energy or high-performance. The sub-threshold region DML achieves minimum-energy. However, sub-threshold region consequence in performance is enormous. In this paper, the working of DML model in the moderate inversion region has been explored. The near-threshold region holds much of the energy saving of subthreshold designs, along with improved performance. Furthermore, robustness to supply voltage and sensitivity to the process temperature variations are presented. Monte carol analysis shows that the projected near-threshold region has minimum energy along with the moderate performance.
The main goal of the research was to obtain a set of data for ability of speech in noise recognition using Polish word test (New Articulation Lists – NAL-93) with two different masking signals. The attempt was also made to standardise the background noise for Polish speech tests by creating babble noise for NAL-93. Two types of background noise were used for Polish word test – the babble noise and the speech noise. The short method was chosen in the study as it provided similar results to constant stimuli method using less word material. The experiment using both maskers was presented to 10 listeners with normal hearing.
The mean SRT values for NAL-93 were −3.4 dB SNR for speech noise and 3.0 dB SNR for babble noise. In this regard, babble noise provided more efficient results. However, the SRT parameter for speech noise was more similar to values obtained for other Polish speech tests. The measurement of speech recognition using Polish word test is possible for both types of masking signals presented in the study. The decision as to which type of noise would be better in practice of hearing aid prosthetics remains an open-end question.