Abstract

One major problem in the design of ultrasonic transducers results from a huge impedance mismatch between piezoelectric ceramics and the loading medium (e.g. gaseous, liquid, and biological media). Solving this problem requires the use of a matching layer (or layers). Optimal selection of materials functioning as matching layers for piezoelectric transducers used in transmitting and receiving ultrasound waves strictly depends on the type of the medium receiving the ultrasound energy. Several methods allow optimal selection of materials used as matching layers. When using a single matching layer, its impedance can be calculated on the basis of the Chebyshev, DeSilets or Souquet criteria. In the general case, the typically applied methods use an analogy to a transmission line in order to calculate the transmission coefficient T. This paper presents an extension of transmission coefficient calculations with additional regard to the attenuation coefficients of particular layers. The transmission coefficient T is optimised on the basis of a genetic algorithm method. The obtained results indicate a significant divergence between the classical calculation methods and the genetic algorithm method.

Go to article

Authors and Affiliations

Tadeusz Gudra
Dariusz Banasiak
Download PDF Download RIS Download Bibtex

Abstract

Linear arrays of ultrasonic transducers are commonly used as ultrasonic probes in medical diagnostics for imaging the interior of a human body in vivo. The crosstalk phenomenon occurs during the operation of transducers in which electrical voltages and mechanical vibrations are transmitted to adjacent components. As a result of such additional excitation of the transducers in the array, the directivity characteristics of the aperture used changes, and consequently there is interference with properoperation of a given array and the emergence of distortions in the obtained ultra sound image that reduce its quality. This paper studies the manner of propagation of mechanical crosstalk in the designed model of a linear array of ultrasonic transducers on the basis of unwanted signals, which appeared on elementary piezo-electric transducers when power is supplied to the selected transducer in the array. The universal model of linear array of ultrasonic transducers, which has been developed, allowed the simulation of mechanical crosstalk, taking in to account the cross-coupling phenomenon in all of its structure with the use of finite elements method (FEM) implemented in COMSOL Multiphysics software. The analysis of crosstalk signals showed that they consist of aggregated pulses propagating with different speeds and frequencies. This signifies the formation of different vibration modes transmitted simultaneously via different paths. The paper is an original approach which enables to identify different vibration modes and estimate their participation in the crosstalk signal and their ways of propagation. Conclusions from the research allow predicting specific design changes which are significant due to the minimization of mechanical crosstalk in linear arrays of ultrasonic transducers.

Go to article

Authors and Affiliations

Mateusz Celmer
Krzysztof J. Opieliński
Download PDF Download RIS Download Bibtex

Abstract

The paper presents results of numerical calculations and experimental data on the directional pattern of two 38-element parametric arrays composed of ultrasound sources. Two types of antenna arrays are considered, namely with parallel and coaxial connections of ultrasonic transducers (elements). The results of selecting and functional testing of unit elements are described in this paper. It is found that in the coaxial element connection of the antenna array, the level of side lobes is higher than that in the parallel element connection.

Go to article

Authors and Affiliations

Denis S. Rakov
Aleksandr S. Rakov
Andrey N. Kudryavtsev
Nikolay P. Krasnenko
Yury A. Chursin
Maksim A. Murin
Download PDF Download RIS Download Bibtex

Abstract

The following work presents the idea of constructing a digitally controlled active piezoceramic transducer matrix for ultrasonic projection imaging of biological media in a similar way as in case of roentgenography (RTG). Multielement ultrasonic probes in the form of flat matrices of elementary piezoceramic transducers require attaching a large number of electrodes in order to activate the individual transducers. This paper presents the idea of minimising the number of transducer connections in an active row-column matrix system. This idea was verified by designing a model of a matrix consisting of 16 ultrasonic transducers with electrode attachments optimised by means of electronic switches in rows and columns and miniature transistor switches in the nodes of the matrix allowing to activate selected transducers. The results of measurements and simulations of parameters of the designed matrix show that it is suitable to be used in projection imaging of biological media as a sending probe. In to use the matrix as a universal sending or receiving probe, it was suggested to add further switches that would eliminate the undesired effect of crosstalks in case of switches used for toggling the transducers in the nodes of the matrix.

Go to article

Authors and Affiliations

Krzysztof Opieliński
Tadeusz Gudra
Piotr Pruchnicki
Download PDF Download RIS Download Bibtex

Abstract

The following paper presents an idea of minimising the number of connections of individual piezoelectric transducers in a row-column multielement passive matrix system used for imaging of biological media structure by means of ultrasonic projection. It allows to achieve significant directivity with acceptable input impedance decrease. This concept was verified by designing a model of a passive ultrasonic matrix consisting of 16 elementary piezoceramic transducers, with electrode attachments optimised by means of electronic switches in rows and columns. Distributions of acoustic field generated by the constructed matrix model in water and results of the calculations conformed well.

Go to article

Authors and Affiliations

Krzysztof Opieliński
Tadeusz Gudra
Piotr Pruchnicki