Abstract

Wind constitutes one of the major environmental factors affecting the design and performance of built environment. Each country has its unique climatic wind conditions, and the way in which these are considered and implemented in the structural design, is important. An implementation or adoption of any new engineering design stipulations introduces a formidable challenge to the developers of the standards and the design profession. This has been experienced in some of the countries (e.g. the UK, Australia and the USA), where processes of modernising the outdated codifi cation took place in the past. Although both Poland and South Africa are currently at the early implementation stage of the new wind loading design stipulations, there is a major difference between the circumstances of the two countries. Poland, as an EU member state, has a compulsory obligation to adopt the new uniform standarisation requirements, within a stipulated time-frame. The South African code developers, after a thorough investigation process which will be highlighted in the paper, decided voluntarily to adopt the Eurocode as the primary model document.

Go to article

Authors and Affiliations

A. Goliger
J. Żuranski
M. Giżejowski
M. Gaczek
J. Retief
A. Kruger
P. Dunaiski
S. Fiszer
M. Ćwik
Download PDF Download RIS Download Bibtex

Abstract

The paper presents an analysis of a 100-meter wind measurement guyed mast located in the north-western part of the United States, in the state of Oregon. Using the RFEM software [1], the influence of the wind on the mast was analyzed according to the guidelines of two standards: American TIA-222-H [2] and European EN 1993-3-1 [3]. The purpose of this work is to show the differences between the results of static computations of the mast in terms of the considered standards. Due to the limited content of the work, the icing load on the structure was ignored in the analysis and the focus was on determining the response of the mast only in terms of wind action. The author tried to describe the differences in this respect between the standard guidelines [2] and [3]. The comments and conclusions regarding the analysis of guyed masts presented in the article have some practical aspects and can be used in design practice.
Go to article

Authors and Affiliations

Renata Pigoń
1
ORCID: ORCID

  1. Koszalin University of Technology, Faculty of Civil Engineering, Environmental and Geodesy, ul. Sniadeckich 2, 75-453 Koszalin, Poland

This page uses 'cookies'. Learn more