Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 4
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Due to the strength of Willlard V.O. Quine’s attack on the notion of analyticity, the reputation of this concept in philosophy has been considerably shaken. However, not everybody was convinced by Quine’s argument. Among those who decided to defend the dichotomy between analytic and synthetic sentences were two English ordinary language philosophers: Paul Grice and Peter Strawson. Their views are the main subject of the presented article. It consists of five parts. After outlining the basic distinctions connected with analyticity in Part One, the main elements of Quine’s critique of analyticity are delineated in Part Two. Part Three includes Grice’s and Strawson’s response to this critique. Part Four, perhaps surprisingly, describes some decisions by the Polish administrative courts, concerning the interpretation of the concept of ‘widow’ according to the article 20 paragraph 3 of the Act on the Combatant and Victimized Persons. In the final, Part Five, an attempt is made to establish the thesis that analytic sentences are not immune to criticism and may in fact be contested, though their effective abolition may require substantial argumentation and theoretical considerations. This opens a new possibility of using the notion of analyticity in conceptual analysis in jurisprudence.

Go to article

Authors and Affiliations

Michał Pełka
Download PDF Download RIS Download Bibtex

Abstract

This study aimed to evaluate the concentrations of α1-acid glycoprotein (AGP), haptoglobin (Hp), serum amyloid-A (SAA) and ceruloplasmin (Cp) in healthy and various diseased cats and establish reference intervals (RIs) for these acute phase proteins (APPs) in healthy cats. The animal material of the study consisted of 40 healthy cats and 152 cats with various diseases. The serum APPs in the diseased group were higher than those in the healthy group, and age affected Cp concentration in healthy cats. Also, the systemic inflammatory response syndrome (SIRS) positive (+) group had significantly higher AGP concentrations than the SIRS negative (-) group. In conclusion, this study contributes to the limited number of studies on RIs in serum APPs concentrations in healthy cats. The results of this study suggest that APPs are valuable diagnostic tools for identifying the inflammatory processes of various diseases, and AGP concentration could help determine the severity of the inflammatory condition.
Go to article

Authors and Affiliations

G.E. Tuna
1
B. Ulutas
1

  1. Department of Internal Medicine, Veterinary Faculty, Adnan Menderes University, Işıklı St. No: 805, 09020 Efeler/AYDIN09100 Aydın, Turkey
Download PDF Download RIS Download Bibtex

Abstract

Outdoor lighting is an important element in creating an evening and nocturnal image of urban spaces. Properly designed and constructed lighting installations provide residents with comfort and security. One way to improve the energy efficiency of road lighting installation is to replace the electromagnetic control gear (ECG) with electronic ballasts (EB). The main purpose of this article is to provide an in-depth comparative analysis of the energy efficiency and performance of HPS lamps with ECG and EB. It will compare their performance under sinusoidal and nonsinusoidal voltage supply conditions for the four most commonly used HPS lamps of 70 W, 100 W, 150 W, and 250 W. The number of luminaires supplied from one circuit was determined based on the value of permissible active power losses. With the use of the DIALux program, projects of road lighting installation were developed. On this basis, energy performance indicators, electricity consumption, electricity costs, and CO 2 emissions were calculated for one-phase and three-phase installations. The obtained results indicate that an HPS lamp with EB is better than an HPS lamp with ECG in terms of energy quality, energy savings, and environmental impact. The results of this analysis are expected to assist in the choice of HPS lighting technology.
Go to article

Bibliography

  1.  A. Mayeur, R. Bremond, and J.M.Ch. Bastien, “The effect of the driving activity on target detection as a function of the visibility level: implications for road lighting”, Transp. Res. 13(2), 115‒128 (2010).
  2.  Ch. Boomsma and L. Steg, “The effect of information and values on acceptability of reduced street lighting“, J. Environ. Psychol. 39, 22‒31 (2014).
  3.  A. Pena-Garcia, A. Hurtado, and M.C. Aguilar-Luzon, “Impact of public lighting on pedestrians’ perception of safety and well-being”, Saf. Sci. 78, 142‒148 (2015).
  4.  J.D. Bullough, E.T. Donnell, and M.S. Rea, “To illuminate or not to illuminate: roadway lighting as it affects traffic safety at intersections”, Accid. Anal. Prev. 53, 65‒77 (2013).
  5.  A. Jafari-Anarkooli and M. Hadji Hosseinlou, “Analysis of the injury severity of crashes by considering different lighting conditions on two-lane rural roads”, J. Saf. Res. 56, 57‒65 (2016).
  6.  M. Jackett and W. Frith, “Quantifying the impact of road lighting on road safety-a New Zealand study”, IATSS Res. 36, 139‒145 (2013).
  7.  K. Kircher and Ch. Ahlstrom, “The impact of tunnel design and lighting on the performance of attentive and visually distracted drivers”, Accid. Anal. Prev. 47, 153‒161 (2012).
  8.  M. Kostic and L. Djokic, “Recommendation for energy efficient and visually acceptable street lighting”, Energy 34, 1565–1572 (2009).
  9.  D. Campisi, S. Gitto, and D. Morea, “Economic feasibility of energy improvements in street lighting systems in Rome”, J. Clean. Prod. 175, 190‒198 (2018).
  10.  S. Yoomak and A. Ngaopitakkul, “Optimisation of quality and energy efficiency of LED luminaires in roadway lighting systems on different road surfaces”, Sustain. Cities Soc. 38, 333‒347 (2018).
  11.  F. Lecce, G. Salvadoni, and M. Rocca, “Critical analysis of the energy performance indicators for road lighting systems in historical towns of central Italy”, Energy 138, 616‒628 (2017).
  12.  M. Beccali, M. Bonomolo, F. Leccese, D. Lista,, and G. Salvadoni, “On the impact of safety requirements , energy prices and investment costs in street lighting refurbishment design”, Energy 165, 739–759 (2018).
  13.  P. Pracki, A. Wiśniewski, D. Czyżewski, R. Krupiński, K. Skarżyński, M. Wesołowski, and A. Czaplicki, “Strategies influencing energy efficiency of lighting solutions”, Bull. Pol. Acad. Sci. Tech. Sci. 68(4), 711‒719 (2020).
  14.  P.R. Boyce, S. Fotios, and M. Richards, “Road lighting and energy savings”, Lighting Res. Technol. 41, 245‒260 (2009).
  15.  C.C.M. Kyba, A. Hänel, and F. Hölker, “Redefining efficiency for outdoor lighting”, Energy Environ. Sci. 7, 1806‒1814 (2014).
  16.  M. Beccali, M. Bonomolo, G. Ciulla, A. Galatioto, and V. Lo Brano, “Improvement of energy efficiency and quality of street light-ing in South Italy as an action of Sustainable Energy Action Plans. The case study of Comiso (RG)”, Energy 92(3), 394‒408 (2015).
  17.  A. Wiśniewski, “Calculations of energy savings using lighting control systems ”, Bull. Pol. Acad. Sci. Tech. Sci. 68(4), 809‒817 (2020).
  18.  M. IndraalIrsyad and N. Rabindra, “A survey based approach to estimating the benefits of energy efficiency improvements in street lighting systems in Indonesia”, Renew. Sust. Energ. Rev. 58, 1569–1577 (2016).
  19.  S. Pizzuti, M. Annunziato, and F. Moretti, “Smart street lighting management”, Energy Effic. 6, 607–616 (2013).
  20.  D. Radulovic, S. Skok, and V. Kirincic, “Energy Effic. public lighting management in the cities”, Energy 36, 1908–1915 (2011).
  21.  A. Djuretic and M. Kostic, “Comparison of electronic and conventional ballasts used in roadway lighting”, Light. Res. Technol. 46, 407–420 (2014).
  22.  S. Yoomak, Ch. Jettansen, and S. Ngaopitakkul Bunjongjit, “Comparative study of lighting quality and power quality for LED and HPS luminaires in a roadway lighting system”, Energy Build. 159, 542‒557 (2018).
  23.  M.H. Omar, H. Abdul Rahman, M.S. Majid, M.Y. Hassan, and N. Rosmin, “The reduction of total harmonic distortion and electromagnetic interference in high pressure sodium street lighting using single stage electronic ballast”, IEEE International Power Engineering and Optimization Conference (PEOCO) 2012, pp. 230‒235.
  24.  A.A. Mansour and O.A. Arafa, “Comparative study of 250 W high pressure sodium lamp operating from both conventional and electronic ballast”, J. Electr. Syst. Inf. Technol. 1, 234‒254 (2014).
  25.  W. Nsibi, M. Nehdi, A.J. Chammam, A. Sellami, and G. Zissis, “Dimmable electronic ballast for HPS lamp operating in LF”, 7th International Renewable Energy Congress (IREC), Hammamet, Tunisia, 2016, pp. 1‒4.
  26.  M.N. Nehdi, W. Nsibi, A. Chammam, A. Sellami, and G. Zissis, “Frequency dimmable electronic ballast for a 250W HPS lamp”, 7th International Renewable Energy Congress (IREC), Hammamet, 2016, pp. 1‒3.
  27.  R. Sikora and P. Markiewicz, “Assessment of Colorimetric Parameters for HPS Lamp with Electromagnetic Control Gear and Electronic Ballast”, Energies, 13(11), 2909 (2020), doi: 10.3390/en13112909.
  28.  F.B. dos Reis, J. Cesar Marques de Lima, and F.S. dos Reis, “Development of a flexible public lighting system”, 39th Annual Conference of the Industrial Electronics Society (IECON), 2013, pp. 6046‒6051.
  29.  A. Gil-De-Castro, A. Moreno-Munoz, and J.J.G. De La Rosa, “Comparative study of electromagnetic and electronic ballasts – an assessment on harmonic emission”, Electr. Rev.-Prz. Elektrotechniczny 88(2), 288‒294 (2012).
  30.  H. Shu-Hung Chung, N.M. Ho, W. Yan, P. Wai Tam, and S.Y. Hui, “Comparison of Dimmable Electromagnetic and Electronic Ballast Systems—An Assessmenton Energy Effic. and Lifetime”, IEEE Trans. Ind. Electron. 54, 3145‒3154 (2007).
  31.  M.H. Omar, H.A. Rahman, M.S. Majid, N. Rosmin, M.Y. Hassan, and W.Z. Wan Omar, “Design and simulation of electronic ballast performance for high pressure sodium street lighting”, Light. Res. Technol. 45, 729–739 (2013).
  32.  S. Hossein-Hosseini, M. Sabahi, and A. Yazdanpanah-Goharrizi, “An improved topology of electronic ballast with wide dimming range,PFC and low switching losses using PWM-controlled soft-switching inwerter”, Electr. Power Syst. Res. 78, 975–984 (2008).
  33.  A. Burgio and D. Menniti, “A novel technique for energy savings by dimming high pressure sodium lamps mounted with magnetic ballasts using a centralized system”, Electr. Power Syst. Res. 96, 16‒22 (2013).
  34.  K. Hyodhyad and K. Supanaroj, “Energy saving project for street lighting of Provincial Electricity Authority (PEA)”, 2nd Joint International Conference on Sustainable Energy and Environment (SEE2006), 2006, pp. 1‒6.
  35.  W. Yan, S.Y.R. Hui, and S.H. Chung, “Energy saving of large-scale high-intensity -discharge lamp lighting networks using a central reactive power control system”, IEEE Trans. Ind. Electron. 50, 3069‒3078 (2009).
  36.  M. Catelani and L. Ciani, “Experimental tests and reliability assessment of electronic ballast system”, Microelectron. Reliab. 52, 1833–1836 (2012).
  37.  J. Molina, L. Sainz, J.J. Mesas, and J.G. Bergas, “Model of discharge lamps with magnetic ballast”, Electr. Power Syst. Res. 95, 112‒120 (2013).
  38.  C.B. Viejo, J.C.A. Anton, A. Robles, F.F. Martin, J.C. Viera, S. Bhosle, and G. Zissis, “Comparison between different discharge lamp models based on lamp dynamic conductance”, IEEE Trans. Ind. Electron. 47, 1983‒1991 (2011).
  39.  J. Mesasa, L. Sainza, and A. Ferrerb, “Deterministic and stochastic assessment of the harmonic currents consumed by discharge lamps”, Electr. Power Syst. Res. 81, 10–18 (2011).
  40.  I. Azcarate, J.J. Gutierrez, A. Lazkano, P. Saiz, K. Redondo, and L.A. Leturiondo, “Experimental study of the response of efficient lighting technologies to complex voltage fluctuations”, Electr. Power Energy Syst. 63, 499–506 (2014).
  41.  A. Dolara, R. Faranda, S. Guzzetti, and S. Leva, “Power Quality in Public Lighting Systems”, Proceedings of the 14th International Conference on Harmonics and Quality of Power, Bergamo, Italy, 2010, pp. 1‒7.
  42.  A. Gil de Castro, M.A. Moreno, L.V. Pallarés, and A.A. Pérez, “Harmonic Effect in Street Lighting”, Proceedings of the 7th International Conference-Workshop Compatibility and Power Electronics (CPE), Tallinn, Estonia, 2011, pp. 16‒21.
  43.  M.J.H. Orzáez, Róchaz J. Sola, and A. Gago-Calderon, “Electrical consequences of large-scale replacement of metal-halide by LED luminaires”, Light. Res. Technol. 50, 282–293 (2016).
  44.  M.H.J. Bollen, S.K. Rönnberg, E.O.A. Larsson, M. Wahlberg, and C.M. Lundmark, “Harmonic Emission from Installations with Energy- Efficient Lighting”, Proceedings of the 11th International Conference on Electrical Power Quality and Utilisation, Lisbon, Portugal, 2011, pp. 1‒6.
  45.  EN 50160:2007 “Voltage Characteristics of Electricity Supplied by Public Distribution Systems”, European Union: Brussels, Belgium, (2007).
  46.  R. Sikora, P. Markiewicz, and W. Pabjańczyk, “Computing Active Power Losses Using a Mathematical Model of a Regulated Street Luminaire”, Energies 11, 1386‒1406 (2018).
  47.  R. Sikora, P. Markiewicz, and W. Pabjańczyk, “The Active Power Losses in the Road Lighting Installation with Dimmable LED Luminaires”, Sustainability10, 4742‒4760 (2018).
  48.  IEC 60287-1-1, Electric Cables – Calculation of current rating – calculation of losses – Section 1: General, (2006).
  49.  IEEE Std. 1459-2010. Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, or Unbalanced Conditions, (2010).
  50.  Ustawa z dnia 20 maja 2016 r. o efektywności energetycznej, Dz.U. 2016 poz. 831.
  51.  The Energy Effic. Directive (2012/27/EU).
  52.  R.C. Degeneff, T.M. Halleran, T.M. McKernan, and J.A. Palmer, “Pipe – type cable ampacities in the presence of Harmonics”, IEEE Trans. Power Deliv. 8, 1689 –1695 (1993).
  53.  C. Demoulias, D.P. Labridis, P.S. Dokopoulos, and K. Gouramanis, “Ampacity of Low-Voltage Power Cables Under Nonsinusoidal Currents”, IEEE Trans. Power Deliv. 22, 584‒594 (2007).
  54.  J.J. Desmet, G. Vanalme, R. Belmans, and D. Van Dommelen, “Simulation of losses in LV cables due to nonlinear loads”, 2008 IEEE Power Electronics Specialists Conference, Rhodes, Greece, 2008, pp. 785‒790.
  55.  A. Hiranandani, “Calculation of cable ampacities including the effects of harmonics”, IEEE Industry Applications Magazine 4, 42‒51 (1998).
  56.  Z. Gabryjelski and Z. Kowalski, Sieci i urządzenia oświetleniowe. Zagadnienie wybrane, Wydawnictwo Politechniki Łódzkiej, Łódź, 1997.
  57.  EN 13201-5:2015. Light and lighting. Road lighting – Part 5: Energy performance indicators.
  58.  “Electricity price statistics”. [Online] Available: https://ec.europa.eu/eurostat/statistics-explained/pdfscache/45239.pdf.
  59.  Krajowy Ośrodek Bilansowania i Zarządzania Emisjami, “Wskaźniki emisyjności CO2, SO2, NOx, CO i pyłu całkowitego dla energii elektrycznej”. [Online] Available: http://www.kobize.pl/ [in Polish].
Go to article

Authors and Affiliations

Roman Sikora
1
ORCID: ORCID
Przemysław Markiewicz
1
ORCID: ORCID
Paweł Rózga
1

  1. Lodz University of Technology, Institute of Electrical Power Engineering, ul. Stefanowskiego 18/22, 90-924 Lodz, Poland
Download PDF Download RIS Download Bibtex

Abstract

Concentrator photovoltaic (CPV) systems have proven the capability of competing with traditional photovoltaic (PV) systems due to their high efficiency and low area occupancy. Such CPV systems require efficient heat removal auxiliary systems, especially for medium and high optical concentration ratios. Operating a CPV system under a high optical concentration (ratio > 200 X) might require active cooling techniques, which have high operating costs and maintenance. On the other hand, heat pipes (HPs) are widely used in electronic devices for cooling purposes. This work discusses the possibility of operating a CPV system coupled with HPs as a passive cooling technique. Two different HPs with different lengths are used to compare cooling efficiency. Each HP length was tested either in a single or double configuration. Long HPs showed better heat removal compared to a traditional fin-cooling system. CVP cooling with HP systems enhanced the entire electrical output of the cell, mainly at high optical concentration ratios.
Go to article

Authors and Affiliations

Mohammed Al Turkestani
1
ORCID: ORCID
Mohamed Sabry
1 2
ORCID: ORCID
Abdelrahman Lashin
1 3
ORCID: ORCID

  1. Physics Department, College of Science, Umm Al Qura University, Makkah, Kingdom of Saudi Arabia
  2. Solar Physics Lab, National Research Institute of Astronomy and Geophysics, Cairo, Egypt
  3. Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt

This page uses 'cookies'. Learn more