This paper presents the possibility of reducing the demand for nonrenewable primary energy for buildings using a new conceptual adsorption system of cooling and heating supplied by solar energy. Moreover, the aim of this study is to shorten the payback time of investment in the standard adsorption cooling system through its integration with the heating system. Research has been carried out for an energy-efficient medium-sized single-family building with a floor area of 140 m2 and a heat load of 4.2 kW and cold load of 4.41 kW. It has been shown that the use of an adsorption system of cooling and heating supplied by solar energy decreased the demand for nonrenewable primary energy by about 66% compared to the standard building that meets the current requirements.
The efficacy of solar heat in the control of bacterial soft rot of potato tubers was investigated in Maiduguri, semi-arid region of Northeastern Nigeria. Artificially contaminated tubers were exposed to solar heat for duration of 0, 30, 60, 120 and 180 minutes. The results showed that exposures for 120 and 180 minutes gave the highest control of the disease, although during the hot dry season (mean temperature at exposure was 54.6°C) exposure even for 30 minutes gave satisfactory control of the disease. Solar heat can therefore be used to control of bacterial soft rot of potato tubers.
Solar radiation (Rs) is an essential input for estimating reference crop evapotranspiration, ETo. An accurate estimate of ETo is the first step involved in determining water demand of field crops. The objective of this study was to assess the ac-curacy of fifteen empirical solar radiations (Rs) models and determine its effects on ETo estimates for three sites in humid tropical environment (Abakaliki, Nsukka, and Awka). Meteorological data from the archives of NASA (from 1983 to 2005) was used to derive empirical constants (calibration) for the different models at each location while data from 2006 to 2015 was used for validation. The results showed an overall improvement when comparing measured Rs with Rs determined us-ing original constants and Rs using the new constants. After calibration, the Swartman–Ogunlade (R2 = 0.97) and Chen 2 models (RMSE = 0.665 MJ∙m–2∙day–1) performed best while Chen 1 (R2 = 0.66) and Bristow–Campbell models (RMSE = 1.58 MJ∙m–2∙day–1) performed least in estimating Rs in Abakaliki. At the Nsukka station, Swartman–Ogunlade (R2 = 0.96) and Adeala models (RMSE = 0.785 MJ∙m–2∙day–1) performed best while Hargreaves–Samani (R2 = 0.64) and Chen 1 mod-els (RMSE = 1.96 MJ∙m–2∙day–1) performed least in estimating Rs. Chen 2 (R2 = 0.98) and Swartman–Ogunlade models (RMSE = 0.43 MJ∙m–2∙day–1) performed best while Hargreaves–Samani (R2 = 0.68) and Chen 1 models (RMSE = 1.64 MJ∙m–2∙day–1) performed least in estimating Rs in Awka. For estimating ETo, Adeala (R2 =0.98) and Swartman–Ogunlade models (RMSE = 0.064 MJ∙m–2∙day–1) performed best at the Awka station and Swartman–Ogunlade (R2 = 0.98) and Chen 2 models (RMSE = 0.43 MJ∙m–2∙day–1) performed best at Abakaliki while Angstrom–Prescott–Page (R2 = 0.96) and El-Sebaii models (RMSE = 0.0908 mm∙day–1) performed best at the Nsukka station.
Thin film solar cells based on multinary compound Cu(In,Ga)Se2 show record photovoltaic conversion efficiency approaching 20%. Investigation on defect physics in this compound is crucial for making further progress in the technology. In this work we present the results on photocapacitance (PC) and deep level optical spectroscopy (DLOS) for two types of cells – high efficiency Cu(In,Ga)Se2 cell with about 20% of gallium and pure gallium CuGaSe2 device. We show that PC and DLOS, employed as the techniques complimentary to deep level transient spectroscopy DLTS and admittance spectroscopy, are useful methods in providing information on defect levels in solar cells. In particular they are helpful in diffierentiating between levels belonging to the bulk of absorber and to the interface states. We tentatively assign some of the observed deep levels to InCu or GaCu antisites and Cu interstitials.
The proper designing of PV systems requires the use of advanced building energy simulation techniques. It allows to design the best position of the PV array, as well as the right quantity of produced energy in different cases. On the other hand the PV efficiency is not only a constant value but changes according to temperature and solar radiation. This paper is devoted to estimate the simultaneous effect of both weather factors on PV efficiency. The task was achieved by numerical simulation and ESP-r software. Computer simulations have been carried out with the use of the Typical Meteorological Year data for Warsaw (52°N 21°E). The greatest influence of temperature on the efficiency of solar energy conversion was observed for crystalline silicon cells. The influence of the boundary conditions assumed in the study is ignored for amorphous silicon cells in the summer period and regardless of the material type in the winter period.
Studies conducted between December 20. 1978 and February 20. 1979 on Arctowski Station show that daily sums of total radiation ranged from 165.5 to 834.5 mWhr x cm2. Maximal mean hourly radiations were recorded from 12 to 14 hours (39.7—72.4 mWhr x cm2).
In Poland an increase in the of number solar thermal collectors is observed in household applications. For economic and ecological profitability the creation of a solar thermal installation design in a proper manner is essential.
In order to determine solar installations size, software calculating future solar heat gains is used. SHW software is an examples of such software. The aim of this work was to compare the simulation results with the real results of the solar installation operation. The comparison was performed by an example of a single-family house with flat plate collector installations located in south-east Poland. This installation supports domestic hot water preparation in a house occupied by four people (in two-year period of analyses). The additional heat source in this building is a gas boiler. Solar fraction parameter values were chosen for this comparison. Solar fraction is calculated as a ratio of solar heat gains used in the domestic hot water preparation process to the heat desired for domestic hot water preparation. The real results of Solar Fraction turned out to be higher than the simulation results from May to August (there were many days with Solar Fraction = 1). A difference of 20–50 percentage points was observed (Solar Fraction). Apart from this period no special differences were observed.
Additionally analyses of differences between solar heat gains calculated by Get Solar simulation software with real values (for analyzed building) was performed. This simulation analysis was done before process of building installations.
For economic growth of nation, the energy plays an important role. The excessive use of fossil fuels results the increase in global warming and depleting the resources. Due to this reason, the renewable energy sources are creating more attraction for researchers. In renewable energy sector, solar energy is the most abundant and clean source of energy. In solar thermal systems, solar air heater (SAH) is the main system which is used for heating of air. As it is simple in construction and cheaper in cost, it is of main interest for the researchers. The concept of first law and second law of thermodynamics is used for the study of the energy and exergy analysis respectively. The energy analysis is of great importance for the study of process effectiveness while the exergetic analysis is another significant concept to examine the actual behavior of process involving various energy losses and internal irreversibility. For efficient utilization of solar energy, the exergy analysis is very important tool for optimal design of solar air heaters. The aim of the present work is to review the works related to energy and exergy analysis of various types of solar air heaters and to find out the research gap for future work.
This paper presents a critical analysis of a current typical method to measure sensitivity of solar blind ultraviolet cameras using a high temperature blackbody as a calibrated source of ultraviolet light. It has been shown that measurement of sensitivity of solar-blind ultraviolet (SBUV) cameras defined as minimal detectable blackbody irradiance at optics plane of the tested SBUV camera generates inflated, misleading and prone to measurement errors' results that should not be used for evaluation of SBUV cameras' performance.
In this work, two thermal- and air-stable, hole transporting materials (HTM) in perovskite solar cells are analyzed. Those obtained and investigated materials were two polyazomethines: the first one with three thiophene rings and 3,3′-dimethoxybenzidine moieties (S9) and the second one with three thiophene rings and fluorene moieties (S7). Furthermore, presented polyazomethines were characterized by Fourier transform infrared spectroscopy (FTIR), UV–vis spectroscopy, atomic force microscopy (AFM) and thermogravimetric analysis (TGA) experiments. Both polyazomethines (S7 and S9) possessed good thermal stability with a 5% weight loss at 406 and 377°C, respectively. The conductivity of S7 was two orders of magnitude higher than for S9 polymer (2.7 × 10−8 S/cm, and 2.6 × 10−10 S/cm, respectively). Moreover, polyazomethine S9 exhibited 31 nm bathochromic shift of the absorption band maximum compared to S7.
Obtained perovskite was investigated by UV–vis and XRD. Electrical parameters of perovskite solar cells (PSC) were investigated at Standard Test Conditions (STC). It was found that both polyazomethines protect perovskite which is confirmed by ageing test where Voc did not decrease significantly for solar cells with HTM in contrast to solar cell without hole conductor, where Voc decrease was substantial. The best photoconversion efficiency (PCE = 6.9%), among two investigated in this work polyazomethines, was obtained for device with the following architectures FTO/TiO2/TiO2 + perovskite/S7/Au. Stability test proved the procreative effects of polyazomethines on perovskite absorber.
The paper presents a one-dimensional mathematical model for simulating the transient processes which occur in the liquid flat-plate solar collector tubes. The proposed method considers the model of collector tube as one with distributed parameters. In the suggested method one tube of the collector is taken into consideration. In this model the boundary conditions can be time-dependent. The proposed model is based on solving the equation describing the energy conservation on the fluid side. The temperature of the collector tube wall is determined from the equation of transient heat conduction. The derived differential equations are solved using the implicit finite difference method of iterative character. All thermo-physical properties of the operating fluid and the material of the tube wall can be computed in real time. The time-spatial heat transfer coefficient at the working fluid side can be also computed on-line. The proposed model is suitable for collectors working in a parallel or serpentine tube arrangement. As an illustration of accuracy and effectiveness of the suggested method the computational verification was carried out. It consists in comparing the results found using the presented method with results of available analytic solutions for transient operating conditions. Two numerical analyses were performed: for the tube with temperature step function of the fluid at the inlet and for the tube with heat flux step function on the outer surface. In both cases the conformity of results was very good. It should be noted, that in real conditions such rapid changes of the fluid temperature and the heat flux of solar radiation, as it was assumed in the presented computational verification, do not occur. The paper presents the first part of the study, which aim is to develop a mathematical model for simulating the transient processes which occur in liquid flat-plate solar collectors. The experimental verification of the method is a second part of the study and is not presented in this paper. In order to perform this verification, the mathematical model would be completed with additional energy conservation equations. The experimental verification will be carry out in the close future.